Purpose: NA Grout is designed to provide maximum flow, shrinkage compensation and extended working times in an aggregate-free formulation where clearances are minimal, such as the grouting of tendon cables. Extended working time for maximum pumping range.
Type: Grade C
Consistency: Fluid
Uses: Grouting of tight clearances and areas inaccessible with standard non-shrink grouts
Suggested Applications:
  | Tight clearances between precast segments, beam and columns in contact with stressed steel or cables |
  | Anchor bolts, dowels and rods where sanded grouts restrict complete encapsulation |
  | Areas around tension cables and tendons to encapsulate and maximize anchorage |
 |
|

|
|
Packaging
50 lb bags
 |
Physical Properties |
 Compressive Strength (ASTM C-109)
|
SET |
1 DAY |
3 DAYS |
7 DAYS |
28 DAYS |
|
Fluid |
2,300 psi |
5,400 psi |
7,200 psi |
8,300 psi |
Rate of Set (ASTM C-953)
|
SET |
INITIAL |
FINAL |
|
Fluid |
7:15 |
9:50 | *Note: A = 28 second flow cone method (ASTM C-939)
 |
Product Standards & Approvals |

|
|
ASTM C-1107, Grade C, Corp of Engineers CRD C-621 |
03 60 00 GROUTING |
 |
Product Downloads |

InformationProject Profiles
  | Gross_Dam.pdf | 144.50 KB |
 | View the project profile to see NA Grout in action. |
How Much Do I Need?
|