Fast setting, non-shrink precision grout

Purpose: Grouting, anchoring and supporting in applications that require a short turnaround time. Ideal for cold weather placement.
Consistency: Damp pack, plastic, fluid
Uses: Precision grouting Structural grouting Anchoring Low temperature placing requirements
Suggested Applications:
  | Machinery bases, compressors, punch presses, generators |
  | Steel columns, precast columns, crane rails, beams |
  | Guard rails, sign posts, dowels, rods, bolts |
 |
|

|
|
Packaging
50 lb pails
 |
Physical Properties |
 Compressive Strength (ASTM C-109)
|
SET |
4 HOURS |
1 DAY |
3 DAYS |
7 DAYS |
|
Fluid |
1,455 psi |
4,115 psi |
4,685 psi |
5,870 psi | *Note: A = 4.5 qts
Rate of Set (ASTM C-266)
|
SET |
INITIAL |
FINAL |
|
Fluid |
:16 |
:22 | *Note: A = 28 second flow cone method (ASTM C-939)
 |
Product Standards & Approvals |

|
|
ASTM C-1107, Corp of Engineers CRD C-621 |
03 60 00 GROUTING |
 |
Product Downloads |

Information:How Much Do I Need?
|

View the Grouting & Anchoring Products reference chart.
If you experience difficulty opening a document, save it to your local computer before opening it.  The documents above require Adobe Acrobat Reader to view or print.