EG Grout
Purpose:
EG Grout is a blend of Portland cement, admixtures and specialty graded aggregates designed to provide ease-of-placement, maximum bearing and compressive strength performance from plastic to fluid consistency. EG Grout attains high compressive strengths at specified water ratios. This product is non-metallic, non-shrink, non-corrosive and contains no added chlorides.
Packaging:
50 lb bag
Consistency:
Plastic to Fluid
Uses:
- EG Grout is ideal for a wide variety of applications that include:
- Machinery Grouting: Machinery bases, compressors, punch presses, generators
- Structural Grouting: Steel columns, precast columns, crane rails, beams
- Anchoring: Guard rails, sign posts, dowels, rods, bolts, post-tension anchors
Physical Properties
Compressive Strength (ASTM C109 via C1107)
Set |
1 Day |
3 Days |
7 Days |
28 Days |
---|---|---|---|---|
Plastic - B |
3,300 psi |
5,500 psi |
6,500 psi |
7,500 psi |
Flowable - C |
2,500 psi |
4,000 psi |
5,100 psi |
7,200 psi |
Fluid - D |
2,000 psi |
3,400 psi |
4,600 psi |
7,000 psi |
*Note: B = 3.5 qts | C = 4.0 qts | D = 4.75 qts
Rate of Set (ASTM C266)
Set |
Working Time |
Initial |
Final |
---|---|---|---|
Plastic - B |
:50 |
1:20 |
4:00 |
Flowable - C |
2:30 |
3:00 |
4:30 |
Fluid - D |
3:00 |
4:00 |
6:00 |
*Note:
B - 100% - 125% flow table (ASTM C230, 5 drops in 3 seconds)
C - 125% - 145% flow table (ASTM C230, 5 drops in 3 seconds)
D - 28 second flow cone method (ASTM C939)
Product Standards & Approvals
Standards |
Section Number |
---|---|
ASTM C1107 Corp of Engineers CRD C621 |
03 60 00 Grout |