NA Grout
Purpose:
NA Grout is designed to provide maximum flow, shrinkage compensation and extended working times in an aggregate-free formulation where clearances are minimal, such as the grouting of tendon cables. Extended working time for maximum pumping range.
Packaging:
50 lb bag
Consistency:
Fluid
Uses:
NA Grout is ideal for a wide variety of applications that include:
- Grouting of tight clearances between precast segments, beams and columns in contact with stressed steel tendons or cables
- Pumping applications in areas around tensioned cables and tendons to encapsulate and maximize anchorage
Physical Properties
Compressive Strength (ASTM C942 per 4.4.2)
7 Days |
28 Days |
|
---|---|---|
7,000 psi |
10,000 psi |
Rate of Set (ASTM C953)
Working Time |
Set |
---|---|
2:30 |
8:00 |
Product Standards & Approvals
Standards |
Section Number |
---|---|
|
03 60 00 GROUTING |